Overview of v1 DECK simulations (low-res, water cycle)

Description

  • DECKv1 piControl simulation
  • Starting with two options for the final atmospheric tunings with the goal after 50 to 100 years of selecting the one with the smallest long term drift is global surface air temperature:
    • 20180129.DECKv1a_piControl.ne30_oEC.edison : identical tuning as in beta3rc13_1850, but with a slightly updated version of the code base.
    • 20180129.DECKv1b_piControl.ne30_oEC.edison : same, except for a minor retuning of clubb_c14: 1.08 → 1.06. This is expected to only change net TOA fluxes by a few hundreds of a W/m2.
  • Initial conditions from 0331-01-01 of beta3rc13_1850.

Log

  • : initial configuration and testing
  • : simulation started
  • : based on 110 years of piControl simulation, v1b is selected as the final tuning due to its reduced drift.









Edison jobs

20180129.DECKv1a_piControl.ne30_oEC.edison

#Simulation periodYearsNodesBFBFLAGTime stampDuration (hr)Raw core hoursCost per yearEffective SYPDNotes
1

0001-01-01 - 0017-01-01

0017-01-01 - 0021-01-01

16

4

285

285

true

true

180130-111213

180131-235230

45.619319,699.1215,98510.52
20021-01-01 - 0041-01-0120285true180201-18061243.214302,840.9915,14211.1
30041-01-01 - 0055-06-2514285true180208-020622



  • Died because of bus error.
  • MyNERSC not reporting usage data.
40055-01-01 - 0075-01-0120285true180209-143851



  • MyNERSC not reporting usage data.
50075-01-01 - 0094-01-0119285true180211-105622



  • MyNERSC not reporting usage data.
60094-01-01 - 0113-01-0119285true180213-05192843.518297,659.7015,66610.48
  • Stopping v1a since v1b has been selected as the final tuning.

20180129.DECKv1b_piControl.ne30_oEC.edison

#Simulation periodYearsNodesBFBFLAGTime stampDuration (hr)Raw core hoursCost per yearEffective SYPDNotes
10001-01-01 - 0017-01-01

0017-01-01 - 0021-01-01

16

4

285

285

true

true

180130-143234

180201-020421

44.201309,759.4415,48810.86
2

0021-01-01 - 0041-01-01

0041-01-01 - 0042-01-01

20

1

285

285

true

true

180202-091048

180204-045726

46.804328,001.6515,61910.77
30042-01-01 - 0060-11-1918285true180208-043625



  • Running slowly; could not complete 20 years in 48 hours.
  • MyNERSC no longer reporting usage data.
40060-01-01 - 0079-01-0119285true180210-113736



  • MyNERSC not reporting usage data.
50079-01-01 - 0098-01-0119285true180212-08455242.395289,981.8015,26210.76
60098-01-01 - 0117-01-0119285true180214-03094643.365296,614.7015,61110.52
7

0117-01-01 - 0137-01-01

0137-01-01 - 0138-01-01

21285true

180215-223111

180217-175039

45.491311,161.1014,81711.08
80138-01-01 - 0157-08-1619285true180217-20002348.006328,359.9017,2829.50
  • Could not complete 20 years in 48 hours.
90157-01-01 - 0174-10-3117285true180219-20162648.002328,335.2019,3148.5
  • Very slow; ran out of time.
100174-01-01 - 0193-01-0119285true180222-08013046.581318,612.9016,7699.79
110193-01-01 - 0211-01-0118285true180224-06362341.618284,663.7015,81510.38
120211-01-01 - 0229-01-0118285true180226-00132542.829292,951.5016,27510.09
130229-01-01 - 0247-01-0118285true180227-19030642.325289,504.9016,08410.21
140247-01-01 - 0265-01-0118285true180301-13224643.305296,204.3016,4569.98
150265-01-01 - 0283-01-0118285true180303-08411442.931293,650.7016,31410.06
160283-01-01 - 0302-01-0119285true180305-03365444.018301,083.5015,84610.36
170302-01-01 - 0321-01-0119285true180306-23380544.412303,777.7015,98810.27
180321-01-01 - 0340-01-0119285true180308-20023144.828306,622.0016,13810.17
190340-01-01 - 0359-01-0119285true180310-16521443.668298,687.6015,72010.44
200359-01-01 - 0378-01-0119285true180312-16495646.521318,200.6016,7479.80
210378-01-01 - 0397-01-0119285true180314-15212247.400324,217.9017,0649.62
220397-01-01 - 0416-01-0119285true180316-14451342.084287,855.7015,15010.84
230416-01-01 - 0435-01-0119285true180318-08500342.303289,354.8015,22910.78
240435-01-01 -








Code tag/hash

2e145acfa7eaf89d2480c3967a150d4e15cc86e1 (from master)

Run scripts

run_acme.20180129.DECKv1a_piControl.ne30_oEC.edison.csh

run_acme.20180129.DECKv1b_piControl.ne30_oEC.edison.csh

Output files

Files on Edison scratch:

/global/cscratch1/sd/golaz/ACME_simulations/20180129.DECKv1b_piControl.ne30_oEC.edison

Sub-directories

archive/ : short-term archived files

run/ : raw model output files

pp/ : post-processed files

Selected global mean time series

Net TOA radiation:

Surface air temperature:

Net TOA SW and LW:

E3SM Diags

AMWG

A-Prime for DECKv1a

A-Prime for DECKv1b

  • No labels