Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Back to overview of v1 DECK simulations (low-res, water cycle)

Description

  • DECKv1 piControl simulation
  • Starting with two options for the final atmospheric tunings with the goal after 50 to 100 years of selecting the one with the smallest long term drift is global surface air temperature:20180129.DECKv1aDECKv1b piControl simulation: 20180129.DECKv1b_piControl.ne30_oEC.edison : identical tuning as in beta3rc13_1850
  • Based on /wiki/spaces/SIM/pages/478412855, but with a slightly updated version of the code base.
  • 20180129.DECKv1b_piControl.ne30_oEC.edison : same, except for a minor Minor retuning of clubb_c14: 1.08 → 1.06. This is expected to only change net TOA fluxes by a few hundreds of a W/m2.
  • Initial conditions from 0331-01-01 of beta3rc13_1850 /wiki/spaces/SIM/pages/478412855.

Log

  • : initial configuration and testing
  • : simulation started
  • : based on 110 years of piControl simulation, v1b is selected as the final tuning due to its reduced drift.

Image Removed

Edison jobs

20180129.DECKv1a_piControl.ne30_oEC.edison

...

0001-01-01 - 0017-01-01

0017-01-01 - 0021-01-01

...

16

4

...

285

285

...

true

true

...

180130-111213

180131-235230

...

  • Died because of bus error.
  • MyNERSC not reporting usage data.

...

  • MyNERSC not reporting usage data.

...

  • MyNERSC not reporting usage data.

...

  • Stopping v1a since v1b has been selected as the final tuning.

Edison jobs

20180129.DECKv1b_piControl.ne30_oEC.edison

#Simulation periodYearsNodesBFBFLAGTime stampDuration (hr)Raw core hoursCost per yearEffective SYPDNotes
10001-01-01 - 0017-01-01

0017-01-01 - 0021-01-01

16

4

285

285

true

true

180130-143234

180201-020421

44.201309,759.4415,48810.86
2

0021-01-01 - 0041-01-01

0041-01-01 - 0042-01-01

20

1

285

285

true

true

180202-091048

180204-045726

46.804328,001.6515,61910.77
30042-01-01 - 0060-11-1918285true180208-043625



  • Running slowly; could not complete 20 years in 48 hours.
  • MyNERSC no longer reporting usage data.
40060-01-01 - 0079-01-0119285true180210-113736



  • MyNERSC not reporting usage data.
50079-01-01 - 0098-01-0119285true180212-08455242.395289,981.8015,26210.76
60098-01-01 - 0117-01-0119285true180214-03094643.365296,614.7015,61110.52
7

0117-01-01 - 0137-01-01

0137-01-01 - 0138-01-01

21285true

180215-223111

180217-175039

45.491311,161.1014,81711.08
80138-01-01 - 0157-08-1619285true180217-20002348.006328,359.9017,2829.50
  • Could not complete 20 years in 48 hours.
90157-01-01 - 0174-10-3117285true180219-20162648.002328,335.2019,3148.5
  • Very slow; ran out of time.
100174-01-01 - 0193-01-0119285true180222-08013046.581318,612.9016,7699.79
110193-01-01 - 0211-01-0118285true180224-06362341.618284,663.7015,81510.38
120211-01-01 - 0229-01-0118285true180226-00132542.829292,951.5016,27510.09
130229-01-01 - 0247-01-0118285true180227-19030642.325289,504.9016,08410.21
140247-01-01 - 0265-01-0118285true180301-13224643.305296,204.3016,4569.98
150265-01-01 - 0283-01-0118285true180303-08411442.931293,650.7016,31410.06
160283-01-01 - 0302-01-0119285true180305-03365444.018301,083.5015,84610.36
170302-01-01 - 0321-01-0119285true180306-23380544.412303,777.7015,98810.27
180321-01-01 - 0340-01-0119285true180308-20023144.828306,622.0016,13810.17
190340-01-01 - 0359-01-0119285true180310-16521443.668298,687.6015,72010.44
200359-01-01 - 0378-01-0119285true180312-16495646.521318,200.6016,7479.80
210378-01-01 - 0397-01-0119285true180314-15212247.400324,217.9017,0649.62
220397-01-01 - 0416-01-0119285true180316-14451342.084287,855.7015,15010.84
230416-01-01 - 0435-01-0119285true180318-08500342.303289,354.8015,22910.78
240435-01-01 - 0444-01-019285true180320-09434820.661141,320.1015,70210.45
  • Edison going down for maintenance
250444-01-01 - 0463-01-0119285true180321-13305044.578304,915.8016,04810.23
260463-01-01 - 0482-01-0119285true180323-10055842.105287,996.3015,15810.83
270482-01-01 - 0498-10-2816285true180325-04120436.708251,079.3015,69210.46
  • Stopped because of node failure
280498-01-01 - 0501-01-013285true180327-0923246.85446,878.7015,62610.50

Code tag/hash

2e145acfa7eaf89d2480c3967a150d4e15cc86e1 (from master)

Run scripts

...

run_acme.20180129.DECKv1b_piControl.ne30_oEC.edison.csh

...

run/ : raw model output files

pppost/ : post-processed files

Selected global mean time series

Net TOA radiation:

Image Removed

Surface air temperature:

Image Removed

Net TOA SW and LW:

Image Removed

E3SM Diags

...

DECKv1a vs obs

20 years

...

DECKv1b vs obs

20 years

...

DECKv1a vs obs

50 years

...

DECKv1b vs obs

50 years

...

AMWG

...

DECKv1a vs obs

20 years

...

DECKv1b vs obs

20 years

...

DECKv1a vs obs

50 years

...

DECKv1b vs obs

50 years

...

A-Prime for DECKv1a

A-Prime for DECKv1b

...

Files on Edison HPSS:

v1 DECK output HPSS archive

Standard diagnostics (overview page)

PMP diagnostics (link, user name/password: acme/AwesomeModel)

MPAS-Analysis diagnostics

Note about differences between MOC plots here and MOC plots in a-prime results under Standard diagnostics above: newest MPAS-Analysis takes into account the bolus velocity (eddy effects) from the GM parameterization when computing the MOC. Note that as of May 7th, 2018, a-prime includes the newest MPAS-Analysis (v0.7.5 tag), so in the future a-prime and MPAS-Analysis will be consistent in that sense.

Full ts, 50 year climos
0001-0050 (0001-0050)
0001-0100 (0051-0100)
0001-0150 (0101-0150)
0001-0200 (0151-0200)
0001-0250 (0201-0250)
0001-0300 (0251-0300)
0001-0350 (0301-0350)
0001-0400 (0351-0400)
0001-0450 (0401-0450)
0001-0500 (0451-0500)

Climate Variability Diagnostics Package (CVDP)

Years 1-300

Years 1-500

Drake passage transport (years 400-500)  Observed range is 120 - 175 Sv

Image Added

Selected global mean time series

Net TOA radiation:

Image Added

Surface air temperature:

Image Added

Net TOA SW and LW:

Image Added


PMP Global RMS

Image Added