Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

On , both v1a and v1b piControl simulations completed 110 years. Analysis of the global surface temperature trend for years 11 to 110 revealed that v1b had the smallest drift of the two. Comparison of climatologies for years 51-100 between the two configurations showed almost no differences, as expected. As a result, v1b was selected as the final tuning for the Water Cycle low-res model.


abrupt-4xCO2 (simulation page)

  • Initialization: 0101-01-01 of v1b piControl

1pctCO2 (simulation page)

  • Initialization: 0101-01-01 of v1b piControl

...